It's important to run enough cables and provide enough jacks in your home to not only provide the services and equipment you currently use but also to account for any future needs including rearranging furniture. In this post I'll go over what I think are the best practices regarding which keystone ports to include in your wall plates.
ANSI/TIA-570-C Residential Structured Wiring Standard
There's actually a standards document that was last updated in 2012 for residential structured wiring, ANSI/TIA-570-C. It provides the minimum outlets to meet 2 different grades of the standard. Each of the grades indicates you should have at least one wall plate in each kitchen, bedroom, family/living/great room, and den/study/office of your home. See my recommendations on http://hibbydabby.blogspot.com /2015/01/where-to-put-structured-wiring-wall.html">where to put voice/data/video outlets in each room of your home.For ANSI/TIA-570-C Grade 1 you should have at least one 4 pair UTP (Cat5e minimum) and one RG6 cable terminated in each wall plate.
For ANSI/TIA-570-C Grade 2 you need at least 2 4 pair UTP (Cat5e minimum) and 2 RG6 cables at each outlet with 2 optional fiber cables.
According to the standard all residential 4 UTP cables should be terminated according to the T568A standard. Which I think makes the most sense. There's a misconception that T568B is newer or better, but it's not. The only difference between the two is that the green pair and orange pair are swapped. T568A is more compatible with phone systems so you can use an RJ45 jack for phone or ethernet depending how you have it terminated on the other end.
My Disagreements with TIA-570-C
RJ12 Phone Jacks Not Allowed
I know landlines aren't a priority for most people these days but I don't agree. In the event of an emergency, the more communications options you have the better. I live in an area where most phone, cable and power lines are above ground on poles. It's not uncommon to lose power or phone service for brief periods of time. Over the past few years there have been some major events in my area. I'm only a few miles away from the site of the World Trade Center. On 9/11 you had a hard time making a cell phone call. During Superstorm Sandy a lot of people had their landline and/or power. Again, cell phone service, even wireless data was very unreliable for those that were able to keep their cell phones charged since even gas was hard to come by due to generator usage and no power at many pumps. If you're already running cables, it's not a big deal to run phone lines too and you can get
I think having a landline with at least one corded phone on each floor is important to have. Even if you don't use it frequently it's good to have for emergencies. You can strip off all the calling features and get the minimum per minute rate with free local calling in most areas for around $15 or less. You might have to spend some time on the phone with your provider but it's worth it. Get rid of all the extras like wire maintenance too. If you're reading this document and doing your own cabling you can manage to fix your phone wires yourself and save over $100 a year.
According to the spec, all Cat5e cables should be terminated at outlets using 8p8c (RJ-45) ports. You also can't split the wiring behind the outlet. That means if you run Cat5e for your phone, have 4 phone lines, one for lines 1&2, the other for lines 3&4, you can't have 2 Cat5e ports wired to 1 cable, which would be the cleanest way to work with most phones. Instead you'd have to wire the 4 line cable to a Cat5e jack then use a break out cable to split the lines externally. I have instructions on http://hibbydabby.blogspot.com /2015/01/rj11-phone-to-rj45-jack.html">how to make a RJ45 to telephone jack breakout cable.
I don't like this at all. My recommendation. Include at least one RJ-11 6p4c Keystone ports on each wall plate. Run Cat5e even though Cat3 is more than fine for standard telephone lines. You can always change out the ports later, just make sure you allow some extra cable at the wall plate and patch panel to allow you to terminate a new connector. You'll only need to punch down the blue and orange pairs. If you have 3 or more lines (or just want 2 phone ports that you can connect to line 1 at the patch panel) punch down the green and brown pairs on a second RJ-11 keystone. See the post on the breakout cable I mentioned previously for more info. As long as you keep each pair twisted as close to the punch down terminal as possible and keep each pair of pairs twisted as much as possible there shouldn't be much risk of noise in the line.
Doing so is cleaner, neater and it helps you differentiate phone and network ports easily. While you can plug a phone plug into a RJ-45 jack, it can sometimes damage the pins. If you do that you'll also best to color code network and phone ports which I don't like. Even though I wound up ordering different colors (blue) for my network Cat5e ports I'm starting to think it looks a bit tacky and too much like an office, which I don't want in my home.
Don't even consider Fiber
My Wall Plate Configuration Suggestions
Wall Plate Labeling and Port Numbering
Bare Minimum
At the very least, every room should have 1 RG6 port, 1 RJ-45 network port and 1 phone port.
Dual VDV Wall Plate
In an ideal world, if money and number of holes you can drill was not an issue, you would run at least 5 cables to each and every wall plate. This will give you the most freedom to rearrange your furniture and equipment without having to alter any of the structured wiring.
This is also the most versatile solution for new construction where you or the builder may not know how the furniture will be arranged.
One Dual VDV and One Dual DV
In your family room for example you'll have two walls plates (as in most rooms). The one closest to the TV will be the Dual Video, Data and Voice configuration while the one near your seating area will just be dual data and voice. You can even omit the phone cable by the TV if you want or run a third network cable.
This is the setup I'm going with. RG-6 cable is the most problematic to run. It has a larger diameter so you can't run that many through holes or conduit. (See my post on http://hibbydabby.blogspot.com /2014/02/how-many-cables-can-you-pull-through.html">how many cables you can fit through a hole.) It's also thicker and harder to pull and more expensive to run and terminate. I do plan on leaving a bit of slack looped up in the wall, attic or unfinished parts of the basement so that if there's ever a need to move the TV to the other side of the room moving the RG6 cables from one wall plate to the other will be easier.